Effectivity: 912 i Series
Edition 1/Rev. 0
d0
535
5.
fm
MAINTENANCE MANUAL
BRP-Powertrain
76-70-00
Page 24
July 01/2012
INSTALLATION
Preparation
-
Clean all parts carefully
-
Remove protective coverings
PRESSURE SENSOR (OPS) - INSTALLA-
TION
Fig. 23
Fig. 24
PRESSURE SENSOR (MAPS_1/MAPS_2) -
INSTALLATION
Fig. 25
Step
Procedure
1
Clean the thread of the pressure sensor.
2
Lubricate the thread of the pressure sen-
sor with LOCTITE 243 and use an
SW 19 open-ended spanner part no.
876075 (or a similar tool) to tighten it.
Tightening torque 15 Nm (88.48 in. lb.).
1. Pressure sensor (OPS)
Step
Procedure
3
Plug the respective wiring harness con-
nector into the corresponding pressure
sensor. See section 76-50-00.
4
Attach cable ties (strain relief).
1. Pressure sensor (OPS)
2. Cable ties
Step
Procedure
1
Clean the thread of the pressure sensor.
2
Tighten the pressure sensor with an SW
21 open-ended spanner part no. 876075
(or similar tool). Tightening torque 15 Nm
(88.48 in. lb.).
3
Plug the respective wiring harness con-
nector into the corresponding pressure
sensor. See section 76-50-00.
4
Attach cable ties (strain relief).
1. Pressure sensors (MAPS_1/MAPS_2)
2. Cable ties