18
Putting into operation
Jelly economy Edition: 01.10
4.7
Pauses and operational breaks
Switch
off
the
implement
if
the
operational break will be more than 1/4
hour.
After switching off, the flow-heater
provides a residual heat for some hours.
Thus, after having been started again,
the implement only needs a few minutes
to
obtain
the
pre-set
processing
temperature.
Before longer operational interruptions
(more than 3 hours) spray the system
empty,
•
in order to save the system from
material-burns.
•
because the jelly will have lost its
ability to jelly after more than 2 - 4
hours of stale.
Immediately switch off the implement
when the system has been emptied.
Material-burns
inside
the
material
channel would be the result when the
system
goes
on
heating
without
material.
Damage due to material channel which
have not been flushed (emptied by
spraying) will not be accepted as claims
under guarantee.
- Switch off the implement if the operational break
will be more than 1/4 hour.
- Before switching off the implement, ensure that it
is empty if the intended operational break will last
longer than 3 hours.
Spraying the system empty
- Disconnect the coupling plug (1).
- Go on spraying your pastry until only an jelly-air-
mixture will emerge the spray gun.
- Secure the spray gun (2) by means of the locking
device (3) against unintended spraying.
- Place the spray gun into the retainer (4).
- Switch off the implement.
- Connect the coupling plug (1) back together.