7.  Flash Power Selection 

  The flash power output is variable over two f-stops from full to one quarter (1/4) power. 

The full stored energy of 125-Watt Seconds (joules) gives a guide number of 41 using a 
50

°

 Keylite reflector and 100 ISO film. Half and quarter power settings are marked on 

the panel by moon phases, and figures. 

 

  Rotating the control (Fig.2. 4) from full to half and half to quarter, gives a reduction in 

output equivalent to 1 f stop for each step. 

 

8. Charge 

  When first switched ‘ON’ the green illuminated ON/OFF switch (Fig.1. 5) will light. When 

the unit has charged to the level set by the flash power selector (Fig.2. 4) the green 
ready LED (Fig.2. 3) will light. Your Esprit 2 125 is now ready to fire. 

 

9. Synchronisation 

  There are several ways to trigger the Esprit 2 125. 

 

  Open Flash: (Fig.2. 5) 

For testing or multiple flash applications the Open Flash Pushbutton can be used. 
 

  Sync Socket: (Fig.1. 4) 

The standard quarter inch jack type socket on the rear panel of the unit may be used for 
direct connection to a camera set to ‘x’ synchronisation. Two Esprit 2 flash units may be 
connected together using a ‘y’ connector. An Infra Red Receiver or Omnicell may also 
be plugged into this socket. 
 

  Photocell: (Fig.2. 2) 

The Esprit 2 125 has a built in photocell enabling the unit to be triggered by the flash 
from any other flash unit or a small camera mounted flash gun. The photocell is 
mounted behind the red transparent cover on the top of the Unit and is continuously on. 
 

 

10.  Modelling Lamp Control 

  With the modelling lamp control switch (Fig.1. 3) in the down position, the modelling 

light is continuously ON. 

 

11.  Fuse (Fig.1. 1) 

  The modelling and flash circuitry is protected by a single 5 amp (F) 20mm fuse mounted 

on the rear panel. Never replace the fuse with one of a different rating. As the fuse may 
blow when the modelling lamp fails always check the fuse when replacing the bulb. A 
spare fuse is supplied in the fuse holder. Always switch OFF the Esprit 2 unit before 
changing the bulb or fuse. 

 
 
 
 
 
 
 
 
 
 

 

 
 
 

 
 
 
 

12.  Fitting / Removing A Reflector 

  A range of reflectors is available for the Esprit 2 125 unit. To fit, slide the neck of the 

reflector over the front of the unit. Align the three pegs on the reflector with the three 
slots in the retaining ring. Press down and turn clockwise to lock. 

 

  To remove reflector, press Latch Knob (Fig.2. 1), turn the reflector fully anti-clockwise 

and withdraw. 

 

  If an umbrella is to be used a ‘Wide Angle Reflector’ should be fitted and umbrella fitted 

through the mounting hole in the mounting bracket on the Wide Angle Reflector and 
locked in position with the knurled screw. 

 

  Note:  Take care when fitting / removing reflectors not to damage the flashtube 

assembly. The flashtube is very delicate, avoid unnecessary handling of the glass tube. 
Always switch off and disconnect from mains supply before fitting / changing the 
flashtube assembly. 

 

Warning High Voltage 

 

Do not touch the flashtube assembly for thirty minutes after 

disconnecting from supply. 

 

13.  Replacement Of Flashtube 

  Ensure that the unit is switched off and disconnected from the mains supply and then 

wait thirty minutes before touching / removing flashtube. Remove the protective cap and 
unwind the twisted Trigger wire from the flashtube support. 
 

  Gently pull the flashtube assembly out of the unit. To replace the assembly, hold the 

flashtube as shown in Fig.3 and taking care to support both legs of the tube. Gently but 
firmly, push the flashtube into position, and wind the Trigger wire around the flashtube 
support. Always replace with the correct flashtube assembly, BW-1074 for UV coated or 
BW-1075 for clear. 

 

 

 
 
 

Fig.3 

Summary of Contents for ESPRIT 2 125

Page 1: ...t 2 125 230V Instructions BW 2055 BWL 0299 1 BOWENS INTERNATIONAL LIMITED 355 Old Road Clacton on Sea Essex CO15 3RH Tel 44 0 1255 422807 Fax 44 0 1255 436342 ESPRIT 2 125 230V BW 2055 OPERATING INSTRUCTIONS ...

Page 2: ......

Page 3: ...erature Apx 5300K UV coated as std Flash Power Control Full to 1 4 2 F stops fully variable Recommended Modelling Lamp 250W 240V Halostar 250W 220V Halostar 275W 220 240V Photoflood BW 1024 BW 1024 A BW 1824 Flash Tube Assembly Clear UV Coated BW 1075 BW 1074 Dimensions L 318mm W 145mm H 145mm Weight 2 2Kg Due to our policy of constant product improvement Bowens International reserve the right to ...

Page 4: ......

Page 5: ...ble materials are placed in close proximity to either the flashtube or modelling bulb when the unit is in use The charging and modelling circuitry of the Esprit 2 125 is protected by a 5A 20mm fuse mounted on the rear panel Fig 1 1 Disconnect the supply before changing the fuse Never replace with a fuse of a different rating A spare 5A fuse is fitted in the fuse holder Switch off and disconnect su...

Page 6: ......

Page 7: ...is protected by a single 5 amp F 20mm fuse mounted on the rear panel Never replace the fuse with one of a different rating As the fuse may blow when the modelling lamp fails always check the fuse when replacing the bulb A spare fuse is supplied in the fuse holder Always switch OFF the Esprit 2 unit before changing the bulb or fuse 12 Fitting Removing A Reflector A range of reflectors is available ...

Reviews: