background image

TOOL OPERATION CHECK:

CAUTION: Remove all fasteners from tool before performing tool operation check.

1. TRIGGER OPERATED TOOL:

A. With finger off the trigger, hold the tool with a firm grip on the handle.

B. Place the nose of the tool against the work surface.

C. Pull the trigger to drive.  Release the trigger and cycle is complete.

CAUTION: THE TOOL WILL CYCLE EACH TIME THE TRIGGER IS PULLED!

2. CONTACT TRIP OPERATION:

A. With finger off the trigger, press the contact trip against the work surface.

THE TOOL MUST NOT CYCLE.

B. Hold the tool off the work surface, and pull the trigger.

THE TOOL MUST NOT CYCLE.

C. With the tool off the work surface, pull the trigger.  

Press the contact trip against the work surface.
THE TOOL MUST CYCLE.

D. Without touching the trigger, press the contact trip against the work surface, 

then pull the trigger.
THE TOOL MUST CYCLE.

3. SEQUENTIAL TRIP OPERATION:

A. Press the contact trip against the work surface, without touching the trigger.

THE TOOL MUST NOT CYCLE.

B. Hold the tool off the work surface and pull the trigger.

THE TOOL MUST NOT CYCLE.
Release the trigger.  The trigger must return to the trigger stop on the frame.

C. Pull the trigger and press the contact trip against the work surface.

THE TOOL MUST NOT CYCLE.

D. With finger off the trigger, press the contact trip against the work surface.  Pull the trigger.

THE TOOL MUST CYCLE.

IN ADDITION TO THE OTHER WARNINGS CONTAINED IN THIS MANUAL
OBSERVE THE FOLLOWING FOR SAFE OPERATION

• Use the STANLEY-BOSTITCH pneumatic tool only for the purpose for which it was 

designed.

• Never use this tool in a manner that could cause a fastener to be directed toward the user 

or others in the work area.

• Do not use the tool as a hammer.

• Always carry the tool by the handle.  Never carry the tool by the air hose.

• Do not alter or modify this tool from the original design or function without approval from 

STANLEY-BOSTITCH, INC.

• Always be aware that misuse and improper handling of this tool can cause injury to 

yourself and others.

• Never clamp or tape the trigger or contact trip in an actuated position.

• Never leave a tool unattended with the air hose attached.

• Do not operate this tool if it does not contain a legible WARNING LABEL.

• Do not continue to use a tool that leaks air or does not function properly. Notify your 

nearest Stanley-Bostitch representative if your tool continues to experience 
functional problems.

-8-

Summary of Contents for RN45B

Page 1: ...REFERENCIA SI TIENE ALGUNA DUDA COMUNÍQUESE CON SU REPRESEN TANTE DE STANLEY BOSTITCH O CON SU DISTRIBUIDOR LIRE ATTENTIVEMENT LE PRÉSENT MANUEL AVANT D UTILISER L APPAREIL PRÉTER UNE ATTENTION TOUTE PARTICULIÈRE AUX CONSIGNES DE SÉCURITÉ ET AUX AVERTISSE MENTS GARDER CE MANUEL AVEC L OUTIL POUR FUTUR RÉFÉRENCE SI VOUS AVEZ DES QUESTIONS CONTACTEZ VOTRE REPRÉSENTANT OU VOTRE CONCESSIONNAIRE STANLE...

Page 2: ...ng the specific requirements established for genuine Stanley Bostitch nails staples and accessories LIMITED WARRANTY Stanley Bostitch Inc warrants to the original retail purchaser that this product is free from defects in material and workmanship and agrees to repair or replace at Stanley Bostitch s option any defective product within 1 year from the date of purchase This warranty is not transfera...

Page 3: ... not pull trigger or depress contact arm while connected to the air supply as the tool may cycle possibly causing injury Always disconnect air supply 1 Before making adjustments 2 When servicing the tool 3 When clearing a jam 4 When tool is not in use 5 When moving to a different work area as accidental actuation may occur possibly causing injury LOADING TOOL When loading tool 1 Never place a hand...

Page 4: ...led thus driving a fastener each time the work is contacted This will allow rapid fastener placement on many jobs such as sheathing decking and pallet assembly All pneumatic tools are subject to recoil when driving fasteners The tool may bounce releasing the trip and if unintentionally allowed to recontact the work surface with the trigger still actuated finger still holding trigger pulled an unwa...

Page 5: ...pneumatic tools A filter will help to get the best performance and minimum wear from the tool The filter must have ade quate flow capacity for the specific installation The filter has to be kept clean to be effective in providing clean compressed air to the tool Consult the manufacturer s instructions on proper maintenance of your filter A dirty and clogged filter will cause a pressure drop which ...

Page 6: ...agazine is not correctly adjusted The magazine contains an adjustable nail platform on which the nail coil rests The nail platform can be moved up and down to three nail settings To change setting pull up on the post and twist to the correct step 1 3 4 45mm nails use bottom step 1 1 4 1 1 2 32 38mm use middle step 3 4 7 8 1 19 22 25mm use top step 3 Load the coil of nails Place the coil of nails o...

Page 7: ...tact trip until the nose touches the work surface and then pull the trigger to drive a fastener Do not press the tool against the work with extra force Instead allow the tool to recoil off the work surface to avoid a second unwanted fastener Remove your finger from the trigger after each operation B RAPID FASTENER OPERATION To operate the tool in this manner hold the tool with the contact trip poi...

Page 8: ...rigger must return to the trigger stop on the frame C Pull the trigger and press the contact trip against the work surface THE TOOL MUST NOT CYCLE D With finger off the trigger press the contact trip against the work surface Pull the trigger THE TOOL MUST CYCLE IN ADDITION TO THE OTHER WARNINGS CONTAINED IN THIS MANUAL OBSERVE THE FOLLOWING FOR SAFE OPERATION Use the STANLEY BOSTITCH pneumatic too...

Page 9: ...TANLEY BOSTITCH Air Tool Lubricant through the air line fitting before testing AIR SUPPLY PRESSURE AND VOLUME Air volume is as important as air pressure The air volume supplied to the tool may be inadequate because of undersize fittings and hoses or from the effects of dirt and water in the system Restricted air flow will prevent the tool from receiving an adequate volume of air even though the pr...

Page 10: ...ring Replace O ring check driver Tool dry lacks lubrication Use STANLEY BOSTITCH Air Tool Lubricant Damaged pusher spring Replace spring Low air pressure Check air supply system to tool Loose magazine nose screws Tighten all screws Fasteners too short for tool Use only recommended fasteners Bent fasteners Discontinue using these fasteners Wrong size fasteners Use only recommended fasteners Leaking...

Page 11: ...ed to allow redressing Always extend the driver the minimum required to allow redressing to restore the driving end several redressings will be possible before this maximum depth is reached DIRECTIONAL EXHAUST DEFLECTOR Loosen screw as shown Adjust to desired exhaust direction and tighten screw ACCESSORIES AVAILABLE BC601 4 oz Stanley Bostitch Air Tool Lubricant BC602 1 pint Stanley Bostitch Air T...