background image

  

Boss Solar Strip Thermal Solar Pool Heating | INSTALLATION MANUAL 

 

 

Revision:

 C 

Revision Date:

 18/11/2021 

 

ANCILLERY INSTALLATION 

 

Drain Down Tube  

 
The Drain Tube allows the supply pipe to slowly drain 
back via the return pipe when the pump is switched 
off. 
 
To install, mark a location on both the supply and 
return pipework, approximately 1 

– 1.5m above the 

pump level against the wall. Drill 8.5mm holes in the 
pipes, using an 8.5mm Drill Bit.  
 
It is highly recommended that you drill a small pilot 
hole first, then drill the holes by running the drill in 
reverse to minimise the risk of pipe shatter. Using a 
blunted drill bit is also preferable. Clean the drill swarf 
and burrs.  
 
Lubricate the and insert the rubber grommets. 
Lubricate the grommets and insert the header barbs. 
Lubricate and slide the tube over the barbs. 
 

 

TufGauge Pressure Gauge 

 
To Install, screw the enclosed brass barb onto the 
thread at the back of the Pressure Gauge using 
Teflon sealing tape and two open end spanners (14 
A/F & 16 A/F). 
 
Drill an 8.5 mm hole in the PVC supply pipe and 
clean the hole of any debris. Insert the tapered end of 
the rubber grommet into the hole. 
 
Lubricate the brass barb and insert it into the rubber 
grommet, ensuring full engagement. Ensure the 
pressure is between 1 and 100 kPa / 15 psi (top fed 
systems 50 kPa / 7 psi max.). 

 

 

 

 

 

STEP 7:

 

Go to the end of the installed strips (known as 

the Loop Return) and fold the strip in on itself. This will 
allow the system to sit lower and neater to the roof. Apply 
a small quantity of Prosil under the loop return to secure 
it. Repeat the process for all looped returns. 

 

Summary of Contents for PROSOLAR

Page 1: ......

Page 2: ...OW IT WORKS 3 REQUIRED TOOLS 3 INSTALLING THE SYSTEM 4 SYSTEM CONFIGURATION 4 MANIFOLD INSTALLATION 5 SOLAR COLLECTOR COIL INSTALLATION 7 ANCILLERY INSTALLATION 8 PLUMB THE SYSTEM TO THE PUMP HOUSE 9 Independent Separate Suction System 9 Simultaneous Integrated Retro Fit Configuration 10 Manual System No Pump or Digital Controller 11 TROUBLESHOOTING RETURN SYSTEM PRESSURE 12 SERVICE AND MAINTENANC...

Page 3: ...c shock and exposure to harmful U V radiation and heat exhaustion It is expected that the reader installing the system uses all necessary safety harnessing scaffolding safety railing and suitable footwear It is also expected that the reader is aware of any electrical shock hazards weather conditions the roof condition roof access methods pitch angle and sun protection when deciding to install the ...

Page 4: ...llectors absorb the sun s heat and transfer it to the pool water The heated water is then returned to the pool Most solar systems include a separate pump and automatic solar controller to maximise heating efficiency and control Thermal Solar Pool Heating systems can be fitted to either new or existing pools REQUIRED TOOLS Standard Chalking Gun Impact Driver or Drill Philips Head Bit Type P PVC Cem...

Page 5: ... switched off Configuration can be installed over multiple roof faces Depending on the roof shape and size the installer has the choice to install the Bottom Feed Solar System in several different configurations This configuration should be adopted wherever possible Bottom Feed System U Loop Configuration Bottom Feed Butterfly This plumbing configuration provides Swift and efficient drain down bac...

Page 6: ... where you wish to install the screws and apply a bead of silicone to the roof Place the EzyClip on top and fix using the two supplied screws Snap the PVC manifold system into place TILE ROOF Lift the tile and slide the EzyTie underneath until it hooks onto the below tile For extra security you may wish to apply a bead of silicone before releasing the tile Lay the PVC Pipe over the top If there is...

Page 7: ...e the hole is clean and free of swarm and burrs STEP 3 Using the supplied silicone lubricant lubricate the 10 1 Manifold grommet Be wary of overspray slip hazard Push the grommet into the drilled hole until it is seated and locked into position STEP 4 Push the Tufman 10 1 manifold into the grommet until it is firmly seated Loop one of the supplied cable ties through 2 holes and secure around the P...

Page 8: ...arantee the strips are in a straight line Once the desired length is reached lead the coil around do not flip and continue unrolling back towards the manifold system STEP 4 Using the solar collector as a guide mark the position of the Tufman 10 1 manifold in the RETURN pipe following the steps outlined above drill and install the manifold If required trim the collector to length using a sharp pair...

Page 9: ...sert the rubber grommets Lubricate the grommets and insert the header barbs Lubricate and slide the tube over the barbs TufGauge Pressure Gauge To Install screw the enclosed brass barb onto the thread at the back of the Pressure Gauge using Teflon sealing tape and two open end spanners 14 A F 16 A F Drill an 8 5 mm hole in the PVC supply pipe and clean the hole of any debris Insert the tapered end...

Page 10: ...x AS2 AS2_2S Digital Solar Controller or similar 1 x Check Valve also known as a Non Return or One Way Valve 1 x Solar Pump that can deliver 3 4 litres per minute per m of collector To Install Identify and confirm the solar Supply and Return lines even if they are labelled This can be achieved by removing the caps if there are any and yelling down the pipes or by pouring water down the line The Su...

Page 11: ...r 1 x Check Valve also known as a Non Return or One Way Valve 2 x PVC Tees 1 x Booster Pump that can deliver 3 litres per minute per m of collector To Install Identify and confirm the Pool Return line that is running from the Pool Filter This can be determined by identifying the return line on a filters multi port valve when using a media filter or when using a cartridge filter identifying the ret...

Page 12: ...stem to operate Before proceeding with this type of installation you should determine the capacity of your existing pool pump The plumbing must be cut in before any other pool equipment e g chlorinator cell heat pump gas heater etc Requires 1 x Check Valve also known as a Non Return or One Way Valve 1 x PVC Tee 1 x 3 Way Manual Valve To Install Identify and confirm the Pool Return line that is run...

Page 13: ...before checking the pool water If the air bubbles consistently stop then the system should be set at an acceptable positive pressure Step 6 Re check that the pressure gauge is within the recommended pressure ranges Step 7 Leave the 2 way valve setting in place permanently by removing the handle If you have installed a system with Plumbing Configuration 3 Manual Driver Valve Connection the followin...

Page 14: ...ed as soon as possible Non Return Valve The non return valve 4 see plumbing diagrams is a critical system component Checked that the 6mm hole drilled in the flap has not become blocked and that the collectors drain fully when the pump stops Vacuum Release Valve The vacuum release valve 9 is a critical system component It should be checked that it is functioning correctly and that collectors drain ...

Reviews: