Safety Instructions

&

Install Guide

Summary of Contents for ControlSpace CC-16

Page 1: ...ControlSpace CC 16 Zone Controller Safety Instructions Install Guide...

Page 2: ...g is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been expos...

Page 3: ...hich can be determined by turning the equipment off and on you are encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Inc...

Page 4: ...zone controller is engineered to provide customized on site controls for ControlSpace sound systems Please read this guide to help you install and use your controller correctly Regulatory information...

Page 5: ...RS 485 port Up to fifteen CC 16 units can be used per each ESP 88 to provide localized control of the system The maximum distance from ESP 88 to CC 16 is 2000 feet As a networked device remote reprogr...

Page 6: ...t the ESP 88 connect the network wire to the RS 485 port and connect the power cable to a power source 5 Run the ControlSpace Designer software to configure and test The CC 16 must be connected to an...

Page 7: ...AWG unshielded CAT 5 Only one pair of wires is needed for the network connection For a daisy chain wired system the maximum cable length is 2000 feet 610 meters For a star topology the maximum length...

Page 8: ...TION Do not install the CC 16 in a box that has AC power mains CAUTION Do not place the power or network cables in the same conduit with the mains wire unless you are sure that special regulatory insu...

Page 9: ...switch addresses Up to fifteen CC 16s can be connected to an ESP 88 and each must have a unique address Use the DIP switches numbered 4 5 6 and 7 on the back of the unit to set the address 1 through 1...

Page 10: ...to terminate the network Termination is accomplished by setting DIP switches 1 and 2 to the ON position In most cases only one CC 16 zone controller the last unit in the daisy chain network furthest...

Page 11: ...e which wire is connected to A and B 2 Connect the network cable to the CC 16 terminal blocks Ensure the wire connected to A on the ESP 88 is the same one connected to A on the controllers and that th...

Page 12: ...e required cable AWG Use the ControlSpace accessory power supply or other suitable supply Individual country requirements are North America Power supplies used in North America must be NRTL listed and...

Page 13: ...e the screws that are appropriate for your wall box the 6 for North American boxes and the M4 for Japanese European and Australian boxes CAUTION Do not overtighten the screws Overtightening may cause...

Page 14: ...e Designer software Refer to the ControlSpace Designer Software user s guide for more information Check that the controls have been linked in the Designer software to signal processing blocks in the E...

Page 15: ...15 Specifications Input voltage 8 18VDC 100mA Max network cable length 2000 feet 609m Number of CC 16 zone controllers per ESP 88 Sound Processor 15 Dimensions...

Page 16: ...FITNESS FOR A PARTICULAR PURPOSE For how long In countries where the duration of the warranty is not determined by statute the Bose Limited Warranty lasts five years from the purchase date For countr...