Cleaning and maintenance
en
41
1.
Turn off the tap so that no more
water can flow in and has to be
drained via the drain pump.
2.
Switch off the appliance. Pull out the
mains plug.
3.
Open and remove the service flap.
4.
Take the drain hose out of the
retainer.
Remove the sealing cap and pour
the water out into a suitable
container.
Replace the sealing cap and place
the drain hose back in the retainer.
5.
Carefully unscrew the pump cover;
residual water may leak out.
Clean the interior, pump-cover
thread and pump housing. The
impeller in the drain pump must be
able to rotate.
Refit the pump cover and screw it on
tightly. The handle must be in a
vertical position.
6.
Place the service flap back on, lock
it into place, and close it.
Note:
To prevent unused detergent
from flowing into the outlet during the
next wash: Pour 1 litre of water into
dispenser
II
and start the
[
Drain
programme: (if only a drained cycle is
required: set
0
Spin Speed
(spin
speed) to
0
).
Drainage hose on the siphon
blocked
1.
Turn the programme selector to
Off
.
Pull out the mains plug.
2.
Loosen hose clip, carefully remove
drainage hose. Residual water may
run out.
3.
Clean drainage hose and siphon
spigot.
4.
Re-attach the drainage hose and
secure the connection point with the
hose clip.