5.
Refit and screw on the pump cover.
The handle must be in a vertical
position.
6.
Close the service flap.
Note:
To prevent unused detergent
from flowing straight into the drain
during the next wash: Pour 1 litre of
water into manual dosing compartment
and start the
[
Drain
programme.
The drain hose at the siphon
is blocked
1.
Turn the programme selector to
Off
.
Pull out the mains plug.
2.
Loosen the hose clamp. Carefully
remove the drain hose; residual
water may leak out.
3.
Clean the drain hose and siphon
connecting piece.
4.
Re-attach the drain hose and secure
the connection point using the hose
clamp.
Filter in the water supply is
blocked
Release water pressure in the supply
hose:
1.
Turn off the water tap.
2.
Select the
Cottons
i
(activate
G
SpeedPerfect
setting) programme.
Note:
If your appliance with
intelligent dosing system
*
, you also
need to deactivate the intelligent
dosing system.
3.
Select the
Start/Reload
A
button.
Allow the programme to run for
approx. 40 seconds.
4.
Turn the programme selector to
Off
.
5.
Pull out the mains plug.
Clean the filters:
1.
Disconnect the hose from the rear of
the appliance.
2.
Use pliers to remove the filter.