VIP X16 XF E
Troubleshooting | en
23
Bosch Sicherheitssysteme GmbH
Installation Manual
F.01U.281.864 | V2 | 2012.12
7.3
Malfunctions with iSCSI connections
7.4
LEDs
The VIP X16 XF E encoder has LEDs on its front and rear panels that show the operating
status and can give indications of possible malfunctions:
ACTIVITY LED
LINK LED
STATUS LED
CONNECT LED
The unit is not
operational after a
firmware upload.
Power failure during
programming by firmware file.
Have the unit checked by
Customer Service and replace it,
if necessary.
Incorrect firmware file.
Enter the IP address of the unit
followed by
/main.htm
in your
Web browser and repeat the
upload.
Placeholder with a red
cross instead of the
ActiveX components.
JVM not installed on your
computer or not activated.
Install Sun JVM from the Bosch
product catalog on the Internet.
Web browser contains
empty fields.
Active proxy server in network.
Create a rule in the local
computer's proxy settings to
exclude local IP addresses.
The
STATUS
LED flashes. Firmware upload failed.
Repeat firmware upload.
Malfunction
Possible causes
Recommended solution
Malfunction
Possible causes
Recommended solution
After connecting to the
iSCSI target, no LUNs are
displayed.
Incorrect LUN mapping during
iSCSI system configuration.
Check the iSCSI system
configuration and reconnect.
After connecting to the
iSCSI target, "LUN FAIL"
appears below a node.
The LUN list could not be read,
as it was assigned to the wrong
network interface.
Check the iSCSI system
configuration and reconnect.
LUN mapping is not
possible.
Some iSCSI systems do not
support the use of an initiator
extension.
Delete the initiator extension.
Flashes:
Traffic on the network.
Lights up:
Network connection established.
Lights up:
Startup in progress.
Flashes:
The unit is faulty, for example following failed firmware
upload.
Lights up:
The unit is switched on and startup completed.
Flashes:
Video connection active.