8.5.2
8.5.3
EX65 Explosion-Protected Camera
Operation | en
37
Lens Wizard submenu
Notice!
These options are set at the factory. There is no need for further modification.
Item
Selection
Description
Lens type
Auto,
Manual, DC-
iris, Video
Auto: - automatically selects the type of lens.
Manual, DC-iris, Video modes: select the matching lens
type to force the camera to the correct lens mode.
Detected
Shows the type of lens detected when auto lens detection
is used.
Set Backfocus
now
Select to fully open the iris. Follow the instructions below
for setting the backfocus for your particular lens type.
After focusing, the object of interest remains in focus
under bright and low light conditions.
Set LVL
Only for video-iris lenses.
Adjust the level control on the lens to center the level
detector indicator (see below).
EXIT
Returns to Install menu.
Synchronization submenu
Item
Selection
Description
Synchronization Internal
Line lock
HV lock,
Genlock,
Internal - for free running camera operation.
Line lock - to lock to the AC power supply
HV lock - locks the camera to the sync signal supplied to
the SYNC connector.
Genlock - locks the camera’s subcarrier to the signal
supplied to the SYNC connector.
Horizontal phase -25 . . 0 . .
+25
Adjusts the horizontal phase offset.
Subphase
0, 2 . . . 358 Adjusts the subcarrier phase.
EXIT
Returns to Install menu.
8.5.4
Alarm I/O submenu
Item
Selection
Description
Alarm input
None, high,
low
Select none to disable the alarm input. Select active-high
or active-low for the alarm input connector.
Alarm action
None,
Mode 1 to 6,
Mono
Selects the operating mode of the camera when the alarm
input is active.