Bosch Solution 2000 Series Troubleshooting Download Page 1

Problem

Action 

• Time is not correct

• Set Date and Time on TouchOne

Touchscreen - Solution 2000/3000

  

Troubleshooting (End Users) 

Solution

• Settings 

->

 Alarm Settings 

->  

Date and Time

Problem

Action 

• WiFi is not connected 

• Connect TouchOne to WiFi

Solution

• Settings 

->

 Touchscreen Settings 

->

 WiFi

Problem

Situation

• The TouchOne 

reboots 

continuously. 

• The TouchOne 

is unable to 

draw enough 

current from 

the Bosch 

Alarm Panel.

Solution

• The Bosch Panel can supply a maximum of 900 mA 

current to externally attached devices (TouchOne, 

Keypads, etc) 

• Should the TouchOne not receive enough current, it 

will continue to reboot. Please contact your installer to 

follow below step: 

1. Install a standalone power supply for the  

TouchOne Screen. (The TouchOne Screen requires 

a 12V 1.5 A power supply.)

Problem

Action

• Customer wants 

to manually 

upgrade the 

firmware 

version of their 

TouchOne

• Over the Air 

software 

update

Solution

• Set Date and Time, connect to WiFi, go to Settings 

->

 

Touchscreen Settings

 ->

 About 

-> 

System Update to 

find if there is a firmware update.

Problem

Situation

• The TouchOne displays a 

Firmware Update - Error 012 

screen 

• The TouchOne 

is detecting 

a different 

firmware version 

from the required 

one.

Solution

• Please wait up to 3 minutes for 

the firmware update process to 

complete.

• If the update fails or stalls, remove 

the 4 pin connector on the back of 

the device, wait 30 seconds and 

plug it back in.

• The firmware upgrade screen will 

load after reboot and continue the 

Firmware Update.

• The TouchOne will reboot once the 

upgrade has completed.

1

1

1

2

2

2

3

3

3

4

4

4

5

5

5

Reviews: