en
Troubleshooting
38
Fault
Cause and troubleshooting
E:18 or indicator for
water supply lights up.
▶
Turn on the water tap.
The flow rate must be at least 10 l/min when the
water supply is open.
The filters in the water connection of the supply or
AquaStop hose are blocked.
1.
Switch off the appliance.
2.
Pull out the mains plug.
3.
Turn off the water tap.
4.
Unscrew the water connection.
5.
Remove the filter from the supply hose
6.
Clean the filter.
7.
Re-insert the filter in the supply hose.
8.
Screw the water connection back on.
9.
Check the water connection for leaks.
10.
Restore the power supply.
11.
Switch the appliance on.
E:22 lights up.
1
Filters are soiled or blocked.
▶
Clean the filters.
→
E:24 lights up.
Wastewater hose is blocked or kinked.
1.
Reposition the wastewater hose without kinks.
2.
Remove residues.
Siphon connection is still sealed.
▶
Check the connection to the siphon and open if ne-
cessary.
Cover of the wastewater pump is loose.
▶
Secure the cover of the Wastewater pump
→
1
Depending on the appliance specifications