702_58300000170749_ara_en_c
Page 51 of 82
This material is intended for the sole use of BSH authorized persons and may contain confidential and proprietary
information. Any unauthorized review, use, copying, disclosure, or distribution in any format is prohibited.
4. Slide water valve up and out of mounting bracket. When
installing new water valve, slide valve flange over bracket
sides and snap valve into bracket
(below)
.
5. Loosen hose clamp and disconnect water inlet hose from
rear of valve.
6. Disconnect wire harness from water valve
(below)
.
7. Unscrew supply hose from water valve.
8. Remove any water from sump & base.
CONNECTION HINTS:
Water connection 3/8” NPT female. Inlet water pressure
range 5 - 120 psi (0.3 – 8.27 bars).
When reconnecting the water supply to the water valve,
don’t overtighten the elbow fitting. Hand tighten snugly.
Do
not
use Teflon tape on water fittings as it can keep
hose seals from seating properly to prevent leaking.
5.6
Drain pump
Access the drain pump from the front of the dishwasher base by
removing the base cover.
Tools needed: T20 Torx & #2 Phillips screwdrivers and pliers
.
1.
Remove parts for bottom front access
– section 5.1.4.1.
2. Disconnect wire harness from drain pump
(below)
.
3. Remove the drain pump by lifting the latch, rotating the
pump clockwise and pulling the pump out
(below)
.
5.7
Aqua sensor
Access the aqua sensor from the front of the dishwasher base by
removing the base cover.