702_58300000170749_ara_en_c
Page 47 of 82
This material is intended for the sole use of BSH authorized persons and may contain confidential and proprietary
information. Any unauthorized review, use, copying, disclosure, or distribution in any format is prohibited.
6. Disconnect top / side wire harnesses from power module
(below)
, making sure to remove the harnesses with their
caps, not individually.
TIP:
Check error codes
before
replacing power
modules. Many good power modules are replaced and
faulty parts aren’t replaced, causing repeat calls.
Not all terminals are used. To protect power modules, two
plugs are used to cover unused terminals.
5.3
Dispenser
Although many dispenser components can be replaced, it’s
quicker to replace the entire dispenser.
5.3.1
To remove dispensers
Dispensers are easily removed from inner doors by removing
outer doors.
Tools needed: T20 Torx, flat blade screwdrivers & gloves
.
1.
Remove outer door
– section 5.1.2.1.
2. Disconnect wire harnesses from dispenser after noting
connector locations
(below left)
.
3. Remove cable guide
(below right).
CAUTION
– 80% of all controls returned
for analysis check out OK. Most control
issues are due to loose connections and
error codes for other parts.