702_58300000170749_ara_en_c
Page 29 of 82
This material is intended for the sole use of BSH authorized persons and may contain confidential and proprietary
information. Any unauthorized review, use, copying, disclosure, or distribution in any format is prohibited.
4.14.3
Backflow valve
The backflow valve is located inside the sump at the outlet to the
drain hose. It prevents waste water from entering the sump.
4.15 Sump filters
The sump contains several types of filters: a filter screen, coarse
filter and micro filter.
5. Coarse filter
6. Microfilter
7. Filter screen
4.16 Tank with base and sump
4.16.1
Base
The plastic assembly is cast into one piece and contains
mounting provisions for all parts mounted to it.
4.16.2
Tank
The ss tank isn’t available as a service part. The top, bottom and
sides are made from 304 ss alloy and the back is made from 430
ss alloy.
3
1
2
2
1
2
1. Backflow valve assembly
2. Flap