en | Central Console, computer setup and programming
Security Escort
2017.08 | V2.18.1.0 | DOC
Training Manual
Robert Bosch (SEA) Pte Ltd
6.4.5
Setting receiver parameters
Create or modify the receivers of the transponder using the features of the
Point
or
Area
Data.
For configuring
Area Data
, refer to the Alarm area setup section. The sections below
explain how to configure the receiver points for the transponder.
Entering point number
Each receiver and alert unit connected to the transponder has a unique
Point Number
assigned during the system design process. This
Point Number
ranges from 0 to 63, and
corresponds to a specific bus number and point multiplex address number. The multiplex
address, set by means of switches on the device (receiver or alert unit) itself, must
correspond with the
Point Number
assigned in the
Transponder Database
.
There is a one-to-one relationship between the
Point Number
and the combination of
Multiplex Point Address
/
Bus Number
pair. For example, a device programmed with
Multiplex Point Address
location 3 on
Bus Number
5 would correspond to the
Point Number
29.
Clicking the
[?]
button to the right of the
Point Number
text box opens a dialog window
displaying the
Point Number
in a table. Clicking on any
Point Number
in the table
automatically closes this window and fills the number in the
Point Number
field on the
Transponder Database
dialog. The
Bus number
and
Point address
are also changed to reflect
the selection.
Figure 6.6: Select Point Dialog with "All Points" Selected
This table provides a quick way to select a particular device without having to translate
between the two numbering (
Bus Number/Point Address
) systems. The three buttons at the
bottom of this dialog allow the user to display: