en | Central Console, computer setup and programming
Security Escort
2017.08 | V2.18.1.0 | DOC
Training Manual
Robert Bosch (SEA) Pte Ltd
Password
This is the password that is used to gain remote access to
the Security Escort System. If the first 5 characters of the
password match the remote systems password, read only
access will be allowed. If the first 8 characters match, you
will be allowed to edit databases remotely (not currently
implemented). If all 12 characters match, you will also be
allowed to change system parameters remotely.
Password verify
For verification, reenter the same password as above.
Disabled
If selected, this system serial port is disabled (default).
History filter output
If selected, this system serial port sends out whatever items
that are selected in the
History Filter
dialog.
Serial Output control
If selected, this system serial port sends out the strings
programmed in the
Serial Output
field of the
Transponder
Database Edit
dialog’s
Area
data. Also see
Serial Output
restore
field below.
Remote system control
If selected, this system is controlled by another system
through a proprietary protocol. This setting can only be used
when two systems are specifically designed to work
together.
Local Service Pages
If selected, system will send service pages via the local port.
Local Security Pages
If selected, system will send security pages via the local
port.
All Local Pages
If selected, system will send both service and security pages
via the local port.
Serial Output restore
This string is transmitted on any system serial port
programmed for
Serial Output control
when the alarm is
cleared. This string is transmitted to the serial output to
reset it to default. Up to 60 characters can be entered.
Control characters can be entered as [^][A] for control A.
Modem init
This is the initialization string transmitted to the modem to
set it up for all communications except paging. Normally,
this setting does not need to change. To allow changes to
this string, hold down the <Shift> + <Ctrl> keys when this
dialog is first opened. This string is specific to each modem
model. The default string should work with most modems.
Modem reset
This is the reset string transmitted to the modem. Normally,
this setting does not need to change. To allow changes to
this string, hold down the <Shift>+ <Ctrl> keys when this
dialog is first opened. This string is specific to each modem
model. The default string should work with most modems.
[Save]
Save the changes and close the dialog window.
[Cancel]
Cancel the changes and close the dialog window..