208
en | System menus and dialogs
Security Escort
2017.08 | V2.18.1.0 | DOC
Training Manual
Robert Bosch (SEA) Pte Ltd
Figure 8.21: Receiver Configuration Dialog
[Put this receiver in setup
mode]
This button initiates the setup process by causing both the
red and green LED of the selected receiver to light up. The
red and green LED will be flashing. On the Central Console,
this button changes the
[Abort setup for this MUX Point]
button to be able to proceed to the next device in the event
that one receiver is not set up properly.
Ambient value
The
Ambient
value, shown above
Auto Advance,
shows the
current ambient level at the receiver. To get an updated
ambient reading, select the point and click the
[Transmit]
button followed by the
[Ambient]
button.
Auto Advance
If this checkbox is checked, the Central Console
automatically selects the receiver with the next higher point
address.
RF micro revision
The receiver’s RF micro revision level is shown below
Auto
Advance
. To get an updated reading, click the
[Revision]
button.