
122
en | Troubleshooting transponders, points, receivers, and alert units
Security Escort
2017.08 | V2.18.1.0 | DOC
Training Manual
Robert Bosch (SEA) Pte Ltd
Database find level
This is the minimum receive level (1-255) that must be heard
before the system will automatically enter the transmitter in the
Subscriber Locate
dialog. It determines the distance the
subscriber’s transmitter must be within the specified ID capture
receiver (set in the
System Preferences
dialog) before the
system will recognize the test.
Locate test level
This is the minimum receive level (1-255) that must be heard
before the system will accept a test generated by a transmitter
other than a guard, to be printed with a location. It determines
the distance the transmitter must be within from a receiver
before the system will recognize the test and print the location.
If the transmitter is too far away from the receiver, that
receiver’s green light will not be displayed, so the guard knows
that they must move closer to the receiver for the test to
register.
Guard tour level
This is the minimum receive level (1-255) that must be heard
before the system will accept a test generated by the guard’s
transmitter to be entered as a location in the guard tour report.
It determines the distance the guard’s transmitter must be
within from a receiver before the system will recognize the test
and create the guard tour entry. If the guard is too far away from
the receiver, that receiver’s green light will not be displayed, so
the guard knows that they must move closer to the receiver for
the test to register.
Guard tour minutes
This setting controls the time spacing, in minutes, for entries of
the guard’s current location in the automatically generated guard
tour report. Therefore if set to 15 minutes, an entry will be
generated each 15 minutes that the guard’s transmitter is within
range of the system.
Watchdog minutes
This setting controls the time spacing, in minutes, for entries of
the guard’s current location in the automatically generated guard
tour report. Therefore if set to 15 minutes, an entry will be
generated each 15 minutes that the guard’s transmitter is within
range of the system.
Popup trouble box contact
information”
Each yellow, pop-up trouble box that is displayed on the Central
Console advises of system problems, containing specific
instructions for the operator. Entries in this text box will be
displayed in the pop-up trouble boxes whenever a system
problem occurs that requires attention. This information usually
includes the name and telephone number of the designated
Security Escort maintenance technicians.
7.8
System Defaults dialog
This dialog allows the names for each class of subscribers to be changed to match the specific
application of this Security Escort System.