background image

1/12

Electrical amplifiers

Type VT-VSPA1-1 and VT-VSPA1K-1

Component series 1X

RE 30111/09.05

Replaces: 02.03

Table of contents

Contents 

Page

Features 

1

Ordering code 

2

Functional description 

2 and 3

Block circuit diagram / pin assignment VT-VSPA1-1 

4

Block circuit diagram / pin assignment VT-VSPA1K-1 

5

Technical data 

6

Output characteristic curves 

7

Indicator / adjustment elements 

8 and 9

Meaning of DIL switches 

10

Unit dimensions 

11

Engineering / maintenance notes / supplementary in for ma tio n  11

Troubleshooting 

12

Features

– Suitable for controlling all direct and pilot operated proportion-

al pressure control valves without electrical position feedback 
and only one solenoid as actuator that are available at the time 
of publication of this data sheet

– Differential input, can be switched between voltage and cur-

rent input

– Additional command value input, 0 to +9 V

– Ramp generator, can be adjusted separately for up and down ramps

– Clocked output stage

– Signal "ready for operation" (VT-VSPA1K-1 only with LED 

indicator lamp)

– Reverse polarity protection for voltage supply

– Cable break detection of current input 4 to 20 mA

– Short-circuit protection of solenoid cable

– Cable break detection of solenoid cable

H5897_d

Suitable card holders for VT-VSPA1-1:

–  Type VT 3002-2X/32, see RE 29928
  Single card holder without power supply unit

Suitable power supply unit:

–  Type VT-NE30-1X, see RE 29929
  Compact power supply unit 115/230 VAC 

 24 VDC, 108 W

Summary of Contents for Rexroth VT-VSPA1-1

Page 1: ...es without electrical position feedback and only one solenoid as actuator that are available at the time of publication of this data sheet Differential input can be switched between voltage and cur rent input Additional command value input 0 to 9 V Ramp generator can be adjusted separately for up and down ramps Clocked output stage Signal ready for operation VT VSPA1K 1 only with LED indicator lam...

Page 2: ... a differential input 1 0 to 10 V With the help of DIL switches 2 it can be configured as cur rent input 4 to 20 mA or 0 to 20 mA If the command value is fed forward by external electronics with a different reference potential e g by a PLC this input must be used When the command value voltage is applied or withdrawn care must be taken that both signal cables are disconnected from or con nected to ...

Page 3: ...s the current command value with clock pulse encoder signal 10 the frequency can be pro grammed with the help of DIL switches 2 The clocked actual current value acts in the solenoid of the valve like a constant current with overlaid dither signal Type VT VSPA1 1 is pro vided with measuring sockets for the internal command value and the actual value The following is valid for the command value 6 V ...

Page 4: ...e I I Soll S1 7 off on I max 1 6 A 0 8 A f 3dB S2 3 S2 4 0 off off 2 5 Hz off on 4 Hz on off f clock S2 5 S2 6 S2 7 100 Hz on on on 200 Hz off on on 300 Hz off off on Comm value 2 S1 1 S1 2 S1 3 0 10 V off off off 0 20 mA on on off 4 20 mA on on on S1 4 on off t max 5 s 1 s Char curve 1 Char curve 2 Ramp up OFF Ramp down OFF 1 Differential input 2 5 15 Summator 3 Max command value attenuator 4 Ram...

Page 5: ...0 off off 2 5 Hz off on 4 Hz on off f clock S2 5 S2 6 S2 7 100 Hz on on on 200 Hz off on on 300 Hz off off on Comm value 2 S1 1 S1 2 S1 3 0 10 V off off off 0 20 mA on on off 4 20 mA on on on S1 4 on off t max 5 s 1 s I Soll 1 Differential input 2 5 15 Summator 3 Max command value attenuator 4 Ramp generator 6 Characteristic curve generator 1 7 Characteristic curve generator 2 8 Current regulator ...

Page 6: ...Ib 50 mA or 100 mA depending on setting with S17 and Zw R130 at Imax 1600 mA Ib 100 mA additionally at Imax 800 mA Ib 0 to 300 mA 20 Adjustable by means of Zw R130 on the printed circuit board at Imax 1600 mA Ib 0 to 600 mA 20 Clock frequency f 100 Hz 200 Hz 300 Hz or 370 Hz 10 each depending on setting with S25 to S27 Signal ready for operation only with VT SPA1 1 Component series 10 when ready f...

Page 7: ...asing current Ib by means of potentiometer Zw R130 on the printed cir cuit board I2 Adjustment range of maximum command value by means of potentiometer Gw A Characteristic curve with factory setting Command value in Output current in mA Iv Biasing current curve 2 qualitative representation I2 Adjustment range of maximum command value by means of potentiometer Gw 1 Characteristic curve 1 qualitativ...

Page 8: ...up Ramp time down w Current command value I Actual current value DIL switch group S1X Potentiometer for bias ing current adjustment DIL switch group S2X Potentiometer for bias ing current adjustment DIL switch group S2X DIL switch group S1X VT VSPA1 1 from component series 11 VT VSPA1K 1 Max command value attenuator Ramp time up Ramp time down Potentiometer for bias ing current adjustment DIL swit...

Page 9: ... 6 7 ON 1 2 3 4 5 6 7 ON 1 2 3 4 5 6 7 1 2 3 4 5 6 7 ON X 1 2 3 4 5 6 7 ON X 1 2 3 4 5 6 7 ON X 0 20 mA ON 1 2 3 4 5 6 7 4 20 mA ON 1 2 3 4 5 6 7 Setting for valve types S15 S17 BR15 BR17 S21 S27 BR21 BR27 Setting valid for all valve types S11 S14 BR11 BR14 DBE M T DBE M 30 DRE M 30 3DRE M 10 1 3DRE M 16 1 DBEP6A DBEP6B 3DREP6A 3DREP6B pumps DRE M 10 5X DRE M 20 5X DBE M 10 5X DBE M 20 5X 3DRE M 1...

Page 10: ...types amplifier cards DBE M T DBE M 30 DRE M 30 DRE M 10 3 DRE M 16 3 DBEP6A DBEP6B 3DREP6A 3DREP6B pumps DRE M 10 5X DRE M 20 5X DBE M 10 5X DBE M 20 5X ZDRE10 Z DBE6 3DRE M 10P 6X 3DRE M 16P 6X DRE ZDRE6 VT 2000 VT 2010 VT 2013 VT 2023 Characteristic curves Basic characteristic curve Characteristic curve 1 Characteristic curve 1 Characteristic curve 2 S15 BR15 OFF ON ON OFF S16 BR16 OFF OFF OFF ...

Page 11: ... voltage 0 V operating voltage For this reason do not connect measuring zero M0 to 0 V operating voltage Use relays with gold plated contacts for passing on command values small voltages small currents Always shield command value cables connect the shield to ground on the card side and leave the other end open Connect the card to ground at terminal 6 or 8 If no system ground is provided connect 0 ...

Page 12: ...rement of contacts 24 ac against 18 ac 2 Fuse on the card defective 3 Internal 9 V operating voltage available on the card 4 When the internal command value potentiometer is used is the jumper from 10 ac to 12 ac plugged 5 Is the external potentiometer properly connected 6 Is the differential input properly connected Check Reference potential to 30 ac 0 to 10 V to 28 ac 7 Is the solenoid properly ...

Reviews: