26/28
Extension and modification
Bosch Rexroth AG
, VT-SVTSY-1-1; RE 29681-B/11.2019
13
Extension and modification
The test device and its accessories must be neither extended nor converted.
Modification of the test device will lead to expiry of warranty.
14 Troubleshooting
14.1 How to proceed for troubleshooting
▶
Have defects rectified exclusively by specialist personnel of Bosch Rexroth AG.
▶
Try to get a clear idea of the cause of error.
14.1.9 Indicators and alarms
The test device is not provided with indicators or alarms for its own error
diagnostics. The LED indicator lamps only serve for error diagnostics of the
connected valves.
15 Technical data
Table 10: Test device VT-SVT-1
Technical data
Operating voltages:
- Battery operation
- Mains operation
9 V (battery, not included in scope of delivery)
12 V DC ±5 %
Current consumption of test device
20 mA (plus valve current)
Dimensions (W x H x D)
95 x 158 x 45 mm
Weight
0.34 kg