12.4.4 Output Frequency Limitation
Direct output frequency limitation
Code
Name
Setting range
Default
Min.
Attri.
E0.08 Maximum output frequency
50.00...400.00 Hz
50.00
0.01
Stop
E0.09 Output frequency high limit
[E0.10]...[E0.08] Hz
50.00
0.01
Run
E0.10 Output frequency low limit
0.00...[E0.09] Hz
0.00
0.01
Run
●
Maximum output frequency
The allowed maximum output frequency of the frequency converter.
●
Output frequency high limit
The allowed maximum output frequency according to the requirements in ac-
tual applications.
●
Output frequency low limit
The allowed minimum output frequency according to the requirements in ac-
tual applications.
Behavior at low speed running
Code
Name
Setting range
Default
Min.
Attri.
E0.15 Low speed running setting
0: Run with 0.00 Hz
1: Run with low limit frequency
0
–
Stop
E0.16 Low speed frequency hystere-
sis
0.00...[E0.10] Hz
0.00
0.01
Stop
By default, the frequency converter runs at 0 Hz when the output frequency is
lower than [E0.10] 'Output frequency low limit'.
●
[E0.15] = 0: Run with 0.00 Hz
Fig. 12-15: Run with 0.00 Hz
VFC 3210
Bosch Rexroth AG
Functions and Parameters
DOK-RCON04-VFC3210****-IT01-EN-P
105/253