6.2.5
Results data transfer with Ethernet
The results data can be transferred after process end (asynchronous) or before process end
(synchronous).
You can find a detailed sequence of the actual PLC signals in chapter
,.
6.2.5.1
Results transfer after process end of an application or single-channel tightening
The following example for a tightening application can be transferred to single-channel tightenings by
replacing the signals for an application (FO x …) by the corresponding signals (CH x.y …).
Fig. 6–16:
Chronological sequence for preparing and asynchronously transferring the tightening results after process end of a
tightening application
The actual end of the tightening application (tightening and process communication unit completed) is
indicated by the evaluation signals (
FO x Ok
,
FO x Nok
) switching from L to H. At this point, the
tightening spindles can be removed from the processed component.
The tightening cycle is ended (PLC signal
FO x CyCmp
) after the results have been prepared and saved
to the mass storage.
The data transfer is implemented independently from the tightening process.
(A)
Tightening application
(B)
Buffer result (mass storage)
(C)
Transfer via FTP
FO x CyCmp
Process end
FO x OK
Application OK
FO x ResRs
Result reset
(1)
Tightening application cycle
(2)
Sequence
(3)
Result processing
(4)
Result invalid
(5)
Result valid
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...