Table 5–6:
PLC output signals for the tightening process of SE/CS
Signals
Function
Description
Ack0-7
Acknowledge Bit 0-7
Acknowledge program bit 0-7.
Only bits 0-5 can be used.
Rdy
Ready
Tightening controller ready
NF
No Fault
No system error
InCy
In Cycle
Start active
InCyCcw
In Cycle Counter Clock Wise
Start active for loosen (prog. 99)
CyCmp
Cycle Complete
Process end
Ok
Result OK
Results OK
Nok
Result NOK
Result not OK
MStop
Motor-breaker
Motor stop at least at one tightening channel of the
modular system or compact system. Signal change
from "high" to "low" in the modular system only with
use of LTE350D or LTS350D (signal change with
LTE350D or LTS350D as of V2.600 of the Rexroth
Tightening System 350).
FtpF
FTP Fault
FTP data transfer error
ToolBn
Tool button
Tool button pressed (ErgoSpin)
CCwSel
Counterclockwise Select (ErgoSpin)
Cw/Ccw reversal switch left (ErgoSpin)
CheckES
1
Check ErgoSpin
Test interval ErgoSpin reached
StartBn
Start button
Start switch pushed (ErgoSpin)
ScanRxID
Scanner read ID
The ID code has been read
EnScanAck
Enable scanner acknowledge
Acknowledges that the scanner is enabled
ScanRdy
Scanner ready
Scanner ready
CntOK
Counter OK
Default value of OK counter reached
CntNOK
Counter NOK
Default value of NOK counter reached
RC0-4
Rework Code Bit 0-4
Rework code bit 0-4
TrigOut
Trigger Out
Trigger output
TorqH
Torque too high
Torque too high
TorqL
Torque too low
Torque too low
AnglH
Angle too high
Angle too high
AnglL
Angle too low
Angle too low
GradH
Gradient too high
Gradient too high
GradL
Gradient too low
Gradient too low
TorqRelH
Torque relative too high
Relative torque too high
TorqRelL
Torque relative too low
Relative torque too low
TorqMaxH
Torque max too high
Maximum torque too high
TorqMinL
Torque min too low
Minimum torque too low
TorqAvrH
Torque average too high
Average torque value too high
TorqAvrL
Torque average too low
Average torque value too low
TorqRgeH
Torque range too high
Torque range too high
TorqRgeL
Torque range too low
Torque range too low
TorqCtrH
Torque control too high
Tightening torque too high
TorqCtrL
Torque control too low
Tightening torque too low
AngTotH
Angle Total Too High
Global angle too high
AngTotL
Angle Total Too Low
Global angle too low
GradAvrH
Gradient average too high
Gradient average value too high
GradAvrL
Gradient average too low
Gradient average value too low
TimeH
Time too high
Time too high
StickSlipH
Stick Slip Too High
Number of stick slips too high
YieldH
Yield too high
Yield point too high
RedH
Redundancy too high
The redundancy is too high
CcwLockAck
Counter clock wise acknowledge
Acknowledges that loosening is disabled
EnAck
Enable acknowledge
Acknowledges enabling
ActEnAck
Active enable acknowledge
Acknowledges enabling of a single tightening process
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...