7.2.3
Connection points of HCS02 power section
Symbols that describe the connection points
Screw terminal block
Spring terminal
Thread
Max. connection
cross section
Max. tightening tor‐
que
Tab. 7-4:
Symbols
Connection point
HCS02
mm
2
(AWG)
Nm
X3, X5,
A, B
1) 2)
4.0 (10)
0.6
C
3)
16.0 (6)
1.7
X6
A, B, C
1.5 (16)
-
X9
B, C
4.0 (10)
1.7
X13
A, B, C
1.5 (16)
-
L+, L-
B, C
M6
6.5
1)
A: HCS02.1E-W0012
2)
B: HCS02.1E-W0028
3)
C: HCS02.1E-W0054, -W0070
Tab. 7-5:
Connection points
7.2.4
Connection points of the control section
See
chapter "CSB02/CSH02 connection points of the control section" on
.
7.2.5
Documentation
Title
Document type
Material number
en (de)
Rexroth IndraDrive supply units, power sections HMV, HMS, HMD,
HCS02, HCS03
Project Planning Manual
R911318790
(R911318789)
Rexroth IndraDrive Drive Controllers, Control Sections CSB02,
CSE02, CSH02, CDB02
Project Planning Manual
R911338962
(R911338961)
Tab. 7-6: