8.2.3
Connect the Motor Fan
Cooling of forced-ventilated motors (design IC416) is done via an electrical
fan which is mounted and separately connected onto the motor. It is operated
with 230 V (star connection) or 400 V (delta connection). The fan is factory-
adjusted designed for 400V.
The electrical connection is done by means of fan terminal box on the fan
housing (see
fig. 8-1 "Connection Overview" on page 66
). Additionally, the
connection scheme is figured within the lid of the fan terminal box and shows
the connection for 230V and 400V. The interconnection is factory-adjusted
designed for 400V.
Fig. 8-8:
Connection scheme motor fan
The following table contains electrical power data of the motor fan with differ‐
ent frame sizes.
DOK-SYTROX-MPES2******-IT01-EN-P
Rexroth Sytronix FcP 50xx/70xx Motor-Pump Unit MPES2
Bosch Rexroth AG
71/143
Connection
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01