48/96
Pressure and flow control system SYDFE1 series 2X, 3X
| Mounting
Bosch Rexroth AG, Edition 10.2021, RE 30011-B
7.4.5 Completing the installation
1.
Remove transport screws, if fitted.
2.
Remove transport protection.
The axial piston pump of the SYDFE1 control system was delivered with
protective covers and plastic plugs or plug screws. These must be removed
before the system can be connected. Use appropriate tools for this.
3
.
Make certain that the sealing and functional surfaces are not damaged.
CAUTION
! Risk of injury caused by ejected plastic plugs!
Operating the SYDFE1 control system with plastic plugs can cause injuries or
damage to the SYDFE1 control system.
▶ Before commissioning, remove all plastic plugs and replace them with suitable,
pressure-proof metal plug screws, because plastic plugs are not pressure-
proof.
Setscrews, if provided, are protected against unauthorized resetting by means
of protective caps. Removing protective caps will void the warranty. If you need
to modify the setting, please contact the responsible Rexroth Service (for
address, see chapter 10.5 “Spare parts“ on page 75).
For the variant with through-drive, mount the auxiliary pump in accordance with
the instructions of the pump manufacturer.
7.5
CONNECTING THE SYDFE1 CONTROL SYSTEM
HYDRAULICALLY
WARNING
Uncontrolled system behavior due to interchanged connections!
Risk of injury! Interchanging the connections will lead to malfunction (e.g. lifting
instead of lowering) and therefore represents a related hazard.
▶ When connecting hydraulic components, observe the specified piping
according to the hydraulic circuit diagram of the machine or system
manufacturer.
NOTICE
Hydraulic pipes and hoses installed under stress!
Hydraulic lines, which are installed under mechanical stress, generate additional
forces during operation, which reduces the service life of the SYDFE1 control
system and the machine or system as a whole.