Transport and storage
Bosch Rexroth AG, Control block SB24/34, RE 66170-B/2019-05-15
If a control block/control block segment is to be stored after disassembly,
preservation for corrosion protection has to be ensured for the full time of storage.
The following instructions only refer to control blocks/control block segments
which are operated with a mineral oil-based hydraulic fluid. Other hydraulic
fluids require other specific preservation measures. In this case, please contact
Bosch Rexorth. For the address, see chapter 10.4 "Spare parts" on page 69.
Bosch Rexroth recommends the following procedure:
1.
Clean the control block/control block segment.
2.
Plug all ports.
3.
Apply mineral oil on the unpainted flange surfaces and external seals of the
control block/control block segment.
4.
Protect sensitive attachments (e.g. actuation elements, sensors, solenoids
or valves) with appropriate measures.
5.
When packaging the control block/control block segment, apply appropriate
measures for corrosion protection.
6.
During storage, protect the control block/control block segment against
shocks. For further conditions, refer to section "Requirements" on page 53
in this chapter.
7.
If necessary, return the control block/control block segment for repair to
Bosch Rexroth.
After removal