Quality code
Settings
Quality code
Configuration of quality codes
The quality code (QC) provides information on the results of a tightening job. If an NOK evaluation is
output, the cause will also be listed.
By assigning the cause of NOK evaluations from tightening processes to specific quality codes, it is
possible to subdivide the results into certain areas. These can be useful e.g. when evaluating the output
tightening results.
*
)MF = monitoring function
There is no counter value for program 99, since it is used as a loosen program.
In addition to the quality code, the PLC OK/NOK signal must also be used for the evaluation. A monitoring
function not selected in the tightening program is regarded as OK on assignment of the quality code.
Table 9–85:
Quality code basic settings
Quality
code
Rework
codes
TJ
*
NOK
TJ
*
OK
all other TJ
*
Category
1
0
–
All OK
System
130
0
Cw = 0
OK/NOK
System
131
0
Ccw = 0
OK/NOK
System
132
0
En = 0
OK/NOK
System
139
0
StartUp
OK/NOK
System
129
0
Fault
OK/NOK
System
2
0
A+
OK/NOK
All
4
0
A-
OK
All
8
0
T+
OK
All
10
0
T+, A+
OK
All
12
0
T+, A-
OK
All
16
0
T-
OK
All
18
0
T-, A+
OK
All
20
0
T-, A-
OK
All
128
0
NOK
OK/NOK
System
Table 9–86:
Quality codes index card - TJ NOK selection criteria
Characteristic
Description
Cw = 0
Canceled by turning the start signal off
Ccw = 0
Canceled by turning the start signal off
En = 0
Canceled by turning the enable signal off
StartUp
NOK start-up test
Fault
Canceled due to system error
T+
upper limit value of torque monitoring exceeded
T-
lower limit value of torque monitoring exceeded
A+
upper limit value of angle monitoring exceeded
A-
lower limit value of angle monitoring exceeded
t+
Time monitoring exceeded