3 608 870 A47
Tightening Technology |
Bosch Rexroth AG 221
Nexo cordless Wi-Fi nutrunner
| 3 608 870 A47/2019-10
Step result parameters
Tightening function parameters
Table 9–66:
Step result parameters and their meaning
Parameter
Meaning
result
Step result OK/NOK
name
Step name
step type
Tightening step type
row
Tightening step row number
column
Tightening step column number
category
Tightening step category
last cmd
Last tightening program command of the step
– TF Angle: Target function Angle
– TF Torque: Target function Torque
– TF Time: Target function Time
– MFs TimeMax: Monitoring function Time, switching
– MFs TorqueMax: Monitoring function Upper torque,
switching
– MFs TorqueMin: Monitoring function Lower torque,
switching
– MFs AngleMax: Monitoring function Angle max, switching
– Cw->0: PLC Signal Cw removal
– Ccw->0: PLC Signal Ccw removal
– En->0: PLC Signal En removal
– SysFault: System errors
– rdy->0: Ready for operation during tightening removed
torque
Step final torque
angle
Step final angle
duration
Step duration in seconds
quality code
Quality code
speed
Set speed
angle threshold nom
Set value of angle counting torque threshold
angle threshold act
Actual value of angle counting torque threshold
Table 9–67:
Tightening function parameters and their meaning
Parameter
Meaning
name
Function name
– TF Angle: Target function Angle
– TF Torque: Target function Torque
– TF Time: Target function Time
– MFs TimeMax: Monitoring function Time, switching
– MFs TorqueMax: Monitoring function Torque max,
switching
– MF TorqueMax: Monitoring function Torque max
– MFs TorqueMin: Monitoring function Torque min, switching
– MF TorqueMin: Monitoring function Torque min
– MF AngleMin: Monitoring function Angle min
– MFs AngleMax: Monitoring function Angle max, switching
– MF AngleMax: Monitoring function Angle max
nom
Set value of function
act
Actual value of function