Bosch Rexroth AG 211
Nexo cordless Wi-Fi nutrunner
| 3 608 870 A47/2019-10
9.8.2.5
My account
Settings
User accounts
My account
This menu item displays the user data of the logged-in user.
9.8.3
Tool display
Settings
Nutrunner display
Use this menu item to define the settings for the display on the portable Nexo cordless Wi-Fi nutrunner.
Also see section
.
General panel
Under
General
, the first screen of the tool display can be defined.
Options panel
Table 9–52:
My account tab
Element
Description
Change password
Click
Change password
to change your password:
1. Enter your old password, then your new password and confirm the latter.
2. Click
Confirm
to confirm the setting.
Table 9–53:
Tool display index card - General panel
Element
Description
First view
Under
First screen
, select the screen to be displayed first on the display of
the Nexo cordless Wi-Fi nutrunner.
Design
Selects the display representation:
Day
or
Night
Language
Selects the display language
Table 9–54:
Tool display index card - Options panel
Element
Description
Allow acknowledgement of system
errors
Enable
Allow acknowledgement of system errors
to acknowledge system
errors using the nutrunner display.
Enforce acknowledgement of NOK
results
As of Nexo firmware version 1200: Enable
Allow acknowledgement of
NOK results
to acknowledge NOK results using the nutrunner display.
Note: Activation does not become active before the first tightening process
after commissioning of the Nexo cordless Wi-Fi nutrunner.
If the
NokAc
PLC input signal is applied to
0.3
-
0.5
in the
tool
PLC module,
NOK results can also be acknowledged at the tool display (program selector
in center position). On application of the
NokAc
PLC input signal in the PLC
table and activation of the
Enforce acknowledgement of NOK results
option, the option has priority on the nutrunner display.
Note: If with activated
Enforce acknowledgement of NOK results
option,
a NOK result occurs, the
Rdy
PLC output signal will be set to "Low"
.
After
confirmation, the signal will change back to “High”.
Show data connection status
As of Nexo firmware version 1200: Enable the check box to display the data
connection status on the nutrunner display.
As of Nexo firmware version 1300,
Display status of the data connection
is activated by default.