ID input
In this step, define the settings for the treatment of the ID input.
General
ID input options
Table 9–24:
Start step dialog - options panel
Element
Description
Show text at the nutrunner display
You can save a text for all job steps. The text will be displayed on the tool
display.
Display time
Indication how long the text will be displayed at the nutrunner display.
Default setting: 1 second
Job abort when NOK result in job
step
Cancels the job as soon as the job step supplies a NOK result.
Delete ID code in end step
Removes the ID code from the input buffer. A new ID code must be
transmitted to the system for the next job.
Click the icon to insert a new ID input step in the job program before the selected step.
Double clicking the step or the respective icon opens the corresponding dialog for entering
the parameters.
Table 9–25:
ID input step dialog - general panel
Element
Description
Identifier
Name for the clear identification of the step.
Name
Step name
Admissible characters are ASCII characters, numbers, spaces, hyphens,
dashes and underscore.
Comments
Description of the step
Admissible characters are ASCII characters, numbers, spaces, hyphens,
dashes and underscore.
Table 9–26:
ID input step dialog - ID input options panel
Element
Description
Source selection ID input
Use this selection to set the source of the ID input of this step.
– Open Protocol
The ID input made available via Open Protocol is used for generating the
ID code.
– Scanner
The valid barcode scanned last is used as ID code.
Choose target for ID input
ID code
(display only):
The ID input is used as ID code for this step.
Masking
Selects where the ID input and the ID code are used. Enter numbers and/or
ranges separated by semicolon. Masking counts up from 1.
Example:
Read-in bar code:
N
25
E
9
XO1234
5
Masking: 1;4;6-11
ID code part:
NEXO1234
Tool display text
You can save a text for all steps. The text will be displayed on the tool display.