3 608 870 A47
Tightening Technology |
Bosch Rexroth AG 139
Nexo cordless Wi-Fi nutrunner
| 3 608 870 A47/2019-10
MID 0072
Upload system errors acknowledgement
MID 0073
Cancel system errors subscription
MID 0074
System error in tightening controller acknowledged
Tool ready status
Only NOK if error comes from tool.
– 1: OK
– 0: NOK
The value consists of one ASCII character.
ID
03
2
Value range
0 – 1
Presetting
-
Example:
Tool ready status
OK
Value
1
1
Time
Date and time when the error occurred.
The value consists of 19 ASCII characters in the format
YYYY-MM-DD:HH:MM:SS.
ID
04
2
Value range
0 – 9, "-" and ":"
Presetting
-
Example:
Time
1/12/2009:11:54:29 AM
Value
1/12/2009:11:54:29 AM
19
Data length revision 001
33
Table 7–41:
MID 0071 revision 001
Parameter
Comments
Bytes
Sent by:
superordinate computer
Acknowledgement for MID 0071
Note: -
Revision:
001
Data field:
is empty, 0 bytes
Possible response:
none
Sent by:
superordinate computer
Cancel system errors subscription
Note:
-
Revision:
001
Data field:
is empty, 0 bytes
Possible responses
MID
Error no. Comment
Command accepted
0005
–
Command error
0004
12
Activation of system errors not available
Sent by:
Tightening controller
The tightening controller sends this message to inform the superior computer that an error has been acknowledged.
Note: -
Revision:
001
Data field:
Error number, 4 bytes
Possible response
MID
Error no. Comment
Acknowledgement System error in
tightening controller acknowledged
0075
–