4.9
MKE118D Technical Data
Technical Data
Designation
Symbol
Unit
MKE118D-012
-⃞⃞⃞-⃞⃞⃞
MKE118B-027
-⃞⃞⃞-⃞⃞⃞
MKE118D-035
-⃞⃞⃞-⃞⃞⃞
Continuous torque at standstill 60
K
M
0_60
Nm
48.0
Continuous current at standstill 60
K
I
0_60(rms)
A
13.0
22.1
29.8
Maximum torque
M
max
Nm
187.0
Maximum current
I
max(rms)
A
58.5
99.6
134.3
Torque constant at 20 °C
K
m
Nm/A
4.29
2.52
1.87
Voltage constant at 20 °C
1)
K
EMK_100
0
V/min
-1
263.5
154.5
114.5
Winding resistance at 20 ℃
R
12
Ohm
0.98
0.350
0.210
Winding inductivity
L
12
mH
15.000
5.70
3.20
Discharge capacity of the compo‐
nent
C
dis
nF
20.2
Number of pole pairs
o
4
Moment of inertia of the rotor
J
rot
kgm²
0.03620
Weight
2)
m
mot
kg
65.0
Thermal time constant
T
th
min
90.0
Maximum velocity
n
max
min
-1
2,000
3,000
Sound pressure level
L
P
dB[A]
61.1 (±3)
Surrounding air temperature dur‐
ing operation
T
amb
°C
0 ... 40
Type of protection according to
IEC 60529
---
IP 65
Insulation class according to DIN
EN 60034-1
---
155
Latest amendment: 2011-08-03
1)
Manufacturing tolerance ±5 %
2)
Mass motor withour holding brake
Fig.4-17:
Technical data MKE
Bosch Rexroth AG
DOK-MOTOR*-MKE*GEN2***-PR06-EN-P
Rexroth MKE Synchronous Motors for Potentially Explosive Areas acc. to ATEX and UL/CSA
42/135
Technical Data