Rated voltage (+/-10 %)
Symbol
U
N
Unit
V
Input voltage of the holding brake
chapter 9.12.1 "Holding Brake Electrically-Released"
.
Rated current
Symbol
I
N
Unit
A
Current consumption of the holding brake.
Connection time
Symbol
t
1
Unit
ms
Time until the holding brake applies.
Disconnection time
Symbol
t
2
Unit
ms
Time until the holding brake releases.
Moment of inertia of the brake
Symbol
J
Br
Unit
kgm
2
The moment of inertia of holding brake must be added to the moment of inertia of the
motor to determine the total moment of inertia.
Bosch Rexroth AG
DOK-MOTOR*-MKE*GEN2***-PR06-EN-P
Rexroth MKE Synchronous Motors for Potentially Explosive Areas acc. to ATEX and UL/CSA
26/135