RE 64025-B/2021-08-12, Bosch Rexroth AG
Troubleshooting |
Control blocks for mobile applications
49
/54
Table 8: Malfunction table
Malfunction
Possible cause
Remedy
Neutral circulation
pressure is too high
No load-sensing unloading
(applies to M4, M6, M7, SP, SX only)
Control spool not in neutral position
With tongue: Check the projection,
see "Technical data sheet".
Pressure in the control covers is too high
(check actuation).
Return flow pressure is too high
Disconnect the return flow from the common return
line; use a separate return line or increase the size of
the line cross section.
Inlet pressure compensator is jammed
Renew the inlet plate.
Movement on consumer
despite neutral position
Control spool is not in neutral position
Pressure in the control covers is too high
(check actuation).
Secondary pressure relief valve leaking or
set too low
Check the setting pressure on the secondary pressure
relief valve.
The control spool leakage is too great
Refer to the data sheet for the leakage values
Install a leak-free lowering brake valve.
No detent function
Restoring force in the direction of actuation
is too great compared to the detent force
(spring)
Remove the detent and clean it.
Detent unit is worn
Renew the detent unit.
Detent release force is
too high
Control spool is jammed
See "Not possible to deflect control spool"
under "Control spool is jammed" at the top of this
table.
Detent unit is damaged
Renew the detent unit.
Detent force is too high
Clean the detent unit and grease it. If this is not
successful, renew the detent unit.
In case of malfunctions caused by contamination, it is essential to check and
possibly improve the quality of the hydraulic fluid through appropriate measures,
such as purging, exchange or additional installation of filters in addition to carrying
out repairs.