34/48 Operation
Bosch Rexroth AG
, M-.SED 10...XN..., RE 22045-XN-B/05.17
9 Operation
9.1 General information
wARnInG
Explosion hazard caused by overheating!
Loss of explosion protection due to overheating.
▶
In case of bank assembly, as long as only one solenoid is energized at a time,
and in case of individual assembly, a maximum hydraulic fluid temperature
of +80 °C may not be exceeded.
▶
In case of bank assembly, if more than one solenoid is energized simultaneously,
a maximum hydraulic fluid temperature of +65 °C may not be exceeded.
▶
If the mating connectors specified in chapter 7.6 "Required accessories"
are used, a maximum ambient temperature of 40 °C may not be exceeded.
Explosion hazard caused by dust accumulations!
If the maximum dust layer thickness of > 50 mm is exceeded, there is an explosion
hazard!
▶
Make sure that the maximum dust layer thickness is not exceeded.
▶
Regularly remove dust accumulations, if required.
CAUTIOn
loud noise!
In case of an unfavorable disposition of valves, resonance or fluid noises,
e.g. whistling, may result. In continuous operation, these noises may cause hearing
damage in persons or damage at the valves.
▶
In this case, contact a service engineer.
Only use the valve within the performance range provided in "Data sheet 22045-XN".
The machine or system manufacturer is responsible for the correct project planning
of the hydraulic system and its control.
Changing the settings at the valve is not admissible.
For information on the operation, please refer to the operating instructions for
the hydraulic system into which the valve is installed.
If errors occur, refer to chapter 14 "Troubleshooting".