22
Bosch Rexroth AG
LTS350D/LTE350D
|
3 608 870 0D6/2011-12
Display
The graphic LC display (Figure 2) enables a
display of the result values (torque, angle,
gradient, time) and error codes. Texts are
shown in 4 lines, each with 8 characters. The
display is permanently backlit (LED).
The contrast can be adjusted in the BS350
operating system, if necessary.
Fig. 2: LC display
Display
The inverse display shows:
– Error
– NOK.
Tab. 1
Target function
Actual value
Upper torque
T
Lower torque
TI
Relative torque, upper
T&
Relative torque, lower
TI&
Angle
A
Input
IN
Time
t
Yield point
Yp
Gradient
G
W OK
571.33
M
35.10
Tab. 2
Monitoring function
Actual value
Torque
T
Relative torque
T&
Torque max. value
T>
Torque min. value
T<
Torque average value
TA
Torque range
T[
Redundancy torque
TR
Tightening from above
TCh
Tightening from below
TCl
Angle
A
Total angle
AO
Redundancy angle
AR
Gradient
G
Gradient average value GA
Time
t
Stick slip
STS
Yield point
Yp
Tab. 3
Function
Actual
value
Displays
Yes/No
Total time
to
Yes
Tab. 4
Event
Marking
Remove start
signal
C(c)w
0
System error
Fault