1.13.1
Electrical connection
Personal injury or property damage by
disconnecting or connecting energized
connectors!
WARNING
●
Disconnect or connect connectors only when they are dry and de-
energized.
●
During operation of the system, all connectors must be securely
connected.
Connecting the connectors
When connecting the hybrid cable connectors, proceed as follows:
1.
Open the bracket at the connection point
2.
Place the connector at the housing in the correct position
3.
Plug in the connector
4.
Close the bracket at the connection point
5.
Assemble the HAS10.1-001 accessory (fixing clip for hybrid cable
connectors):
HAS10.1-001-001
HAS10.1-001-002
Only completely closed brackets ensure that the degree of
protection IP 65 can be attained and activate the vibration
protection.
The HAS10.1-001 accessory (fixing clip for hybrid cable
connectors) increases the vibration resistance of the product and
is mandatory for operating the product.
KSM02 Motor-Integrated Servo Drives Operation in Potential‐
ly Explosive Atmospheres ATEX Directive 2014/34/EU
13/29
Operating instructions
R911379011_Edition 02 Bosch Rexroth AG