Error message number and message
text number
Cause
Recommended to the user
(#32)
The current NC mode cannot be deter‐
mined.
(INcsChannel::GetNcMode)
Timeout too short.
Close and restart the application.
(#50)
The depth of the call stack cannot be de‐
termined.
(IProgChain::GetProgChainDeep)
Timeout too short.
Close and restart the application.
(#51)
The parameters of a subroutine cannot
be determined.
(IProgChain::GetSubProgLevel)
Timeout too short.
Close and restart the application.
(#80)
The connection to the NC was interrup‐
ted.
The connection to the NC was interrup‐
ted.
Close the application, restart it and rees‐
tablish the connection.
(#69)
Failed to establish a connection to the
NC.
(INcConnect::Connect)
Failed to establish a connection to the
NC.
Close the application, restart it and rees‐
tablish the connection.
(#33)
The requested NC mode cannot be set.
(INcsProcess::SetOpMode)
NC mode was changed (e.g. by another
application).
Continue and set the desired NC mode
after a new selection and after starting
the required flow program.
Fig.11-7:
Message reasons are: either OLE error, software problems of the NC
application or MTX-Analyzer application or installation problems
Abbreviations
NC
Numerical Control (System)
CNC
Computerized Numerical Control
CPL
Customer Programming Language
PC
Personal Computer
DDP
Desktop Development Platform
SCP
Scalable Communication Platform
11.2
Energy Monitor
11.2.1
Overview
Purpose of the Energy Monitor
With the energy monitor, the energy consumption of a machine as well as of
individual function modules (electric drives and auxiliary equipment (hydraulic
pumps, cooling lubricant system etc.) are summed up and monitored over de‐
fined time spans.
The energy monitor is part of the MTX interface.
DOK-MTX***-NC*OP***V11-AP01-EN-P
Rexroth IndraMotion MTX 11VRS Standard NC Operation
Bosch Rexroth AG
245/301
Extended Functionality