Rexroth IndraDrive
Status Diagnostic Messages
6-31
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
A0156 Position mode lagless, encoder 1 drive controlled
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
The drive is in position control. The position control loop is closed by
means of a position encoder in the drive. The drive presets the position
command value characteristic internally and follows the command value
without any lag error. (Prerequisite:
P-0-0040, Velocity feedforward
evaluation
= 100%).
"Encoder 1" means that the encoder assigned by means of
P-0-0077,
Assignment motor encoder->optional slot
is used as a control
encoder.
See also Functional Descriptions "Drive-Internal Interpolation" and "Drive-
Controlled Positioning"
A0156 - Attributes
Display:
AF
Mess. no.:
A0156 (hex)
A0157 Position control lagless, encoder 2 drive controlled
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
The drive is in position control. The position control loop is closed by
means of a position encoder in the drive. The drive presets the position
command value characteristic internally and follows the command value
without any lag error. (Prerequisite:
P-0-0040, Velocity feedforward
evaluation
= 100%).
"Encoder 2" means that the encoder assigned by means of
P-0-0078,
Assignment motor encoder->optional slot
is used as a control
encoder.
See also Functional Descriptions "Drive-Internal Interpolation" and "Drive-
Controlled Positioning"
A0157 - Attributes
Display:
AF
Mess. no.:
A0157 (hex)