![Bosch REXROTH IndraDrive Troubleshooting Manual Download Page 398](http://html.mh-extra.com/html/bosch/rexroth-indradrive/rexroth-indradrive_troubleshooting-manual_40580398.webp)
Rexroth IndraDrive
Handling, Diagnostic and Service Functions
10-5
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
XX:F8122
Brief Description:
Error: control section defective
An error occurred during firmware update.
Cause
Remedy
Hardware of control section is defective
Replace control section or entire drive controller; use
hardware configuration of same type
Note:
Only Rexroth service engineers or especially trained users are
allowed to replace the control section. The replacement of the
entire drive controller is described in the Project Planning
Manual for the power section.
Identical cause / remedy:
F8122 Control section defective
XX:F8129
Brief Description:
Error: optional safety module 1 incorrectly
programmed
See
F8129 Firmware of option 1 of safety technology defective
XX:F8130
Brief Description:
Error: optional safety module 2 incorrectly
programmed
See
F8130 Firmware of option 2 of safety technology defective
XX:F8120
Brief Description:
Error: firmware does not support hardware
See
F8120 Invalid control section/firmware combination
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01