C0301 Measuring system unavailable
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
During the execution of the "Set absolute measuring" command (C0300)
the measuring system selected by parameter
P-0-0612, Control word
for setting absolute measuring
was detected to be unavailable.
Cause
Remedy
The command was activated by mistake
Prevent the command from being activated
The measuring system has not been parameterized
Parameterize the measuring system
See also Functional Description "Set Absolute Measuring"
C0301 - Attributes
Display:
C0301
Mess. no.:
C0301 (hex)
C0302 Absolute evaluation of measuring system impossible
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
During the execution of the "Set absolute measuring" command (C0300)
it was detected that absolute evaluation of the selected measuring system
is impossible.
Note:
The "Set absolute measuring" command can only be executed
if there is an absolute measuring system available (see
S-0-0277, Position feedback 1 type
respectively
S-0-0115,
Position feedback 2 type
).
Cause
Remedy
The command was activated by mistake
Prevent the command from being activated
The motor encoder or the optional measuring system
have not been designed as absolute encoders
Equip the motor or the optional measuring system with
an absolute encoder function
See also Functional Description "Set Absolute Measuring"
C0302 - Attributes
Display:
C0302
Mess. no.:
C0302 (hex)
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01