C0220 Error when initializing position of encoder 1
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
While the command
S-0-0128, C0200 Communication phase
4
transition check
is executed, the following checks are carried out for
initializing encoder 1 (motor encoder).
•
offset between high-resolution and low-resolution track
•
communication with encoder
•
generation of position of an initialization track
•
reading of analog signals of an initialization track
If the motor encoder is an HSF encoder, the following checks are
additionally carried out
•
access of angle correction data
•
pointer length of analog signals of an initialization track
If one of the above checks fails, the transition command error C0220 is
generated.
Cause
Remedy
Motor encoder cable defective
Check and if necessary replace motor encoder cable
Motor encoder defective or error in micro controller
of measuring system
Replace motor
Measuring system interface defective
Have measuring system interface replaced by service
department
For removing command errors see "Command Errors"
C0220 - Attributes
Display:
C0220
Mess. no.:
C0220 (hex)