Rexroth IndraDrive
Command Diagnostic Messages
9-23
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
C0111 ID9 + Record length - 1 > length MDT (S-0-0010)
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
During the execution of the command
S-0-0127, C0100 Communication
phase 3 transition check
an error was detected.
The position of the data record in the master data telegram (MDT)
(S-0-0009) plus the length of the data record in the MDT for the drive is
greater than the total length of the MDT (S-0-0010).
Ursache
Abhilfe
Parameterization of
S-0-0009, Position of data
record in MDT
and
S-0-0010, Length of master
data telegram
is incorrect
Correct the parameterization of
S-0-0009, Position of
data record in MDT
and
S-0-0010, Length of master
data telegram
Note:
The definition of the S-0-0009 and S-0-0010 parameters is the
responsibility of the control unit manufacturer and is specified
by SERCOS.
C0111 - Attributes
Display:
C0111
Mess. no.:
C0111 (hex)
C0112 TNcyc (S-0-0001) or TScyc (S-0-0002) error
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
During the execution of the command
S-0-0127, C0100 Communication
phase 3 transition check
an error with regard to the SERCOS timing
settings was detected.
Cause
Remedy
Setting of parameters
S-0-0001, NC Cycle time
(TNcyc)
or
S-0-0002, SERCOS Cycle time (TScyc)
is incorrect
Correct parameters
S-0-0001, NC Cycle time (TNcyc)
and
S-0-0002, SERCOS Cycle time (TScyc)
.
There are settings of 500
µ
s for control section
ADVANCED (or 1 ms for control section BASIC) or
integral multiples of 1 ms allowed.
Note:
The definition of the S-0-0001 and S-0-0002 parameters is the
responsibility of the control unit manufacturer and is specified
by SERCOS.
For removing command errors see "Command Errors"
C0112 - Attributes
Display:
C0112
Mess. no.:
C0112 (hex)