F8015 Automatic commutation: timeout
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
During the execution of the automatic commutation offset determination
(after drive enable) an error was detected.
Cause
Remedy
An error occurred in internal signal generator used
for determining commutation offset
Switch the drive off and on again. If the error continues
to be signaled, contact our service department.
The commutation setting with motion by means of the sine-wave method
is completed when the axis, after commutation offset determination, has
been moved back to the initial position at which it was before the start. If
this is impossible, the error F8015 is generated.
Cause
Remedy
Axis cannot be moved back to position at which it
was at beginning of commutation determination
Check mechanical axis system, remove blocking or
stiffness
F8015 - Attributes
Display:
F8015
Mess. no.:
F8015 (hex)
Saturation Method
Sine-Wave Method