7-10
Error Messages
Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
F8014 Automatic commutation: overcurrent
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
The actual current value amplitude resulting from automatic commutation
offset determination is monitored. When a maximum value is exceeded,
the error F8014 is generated.
Cause
Remedy
Amplitude of actual current value is higher than
allowed maximum current
Reduce signal voltage (
P-0-0506, Voltage amplitude
for angle acquisition
) or increase signal frequency
(
P-0-0507, Test frequency for angle acquisition
)
- or -
With
P-0-0506, Voltage amplitude for angle
acquisition
=0 start automatic determination of
appropriate values
Note:
If error occurs repeatedly, please contact our service
department.
F8014 - Attributes
Display:
F8014
Mess. no.:
F8014 (hex)
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01