MPH-02, MPB-02, MPD-02
Handling, Diagnostic and Service Functions
10-95
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
bit 0-11:
parameter number
(0*0001...0*FFF)
bit 12-14: parameter set
(0...7)
bit 15:
parameter type*
bit 0-2:
parameter type*
bit 3-7:
reserve
(always 0)
0000 S-parameter (drive)
0001 P-parameter (drive)
0010 not used in the drive
0100
not used in the drive
1000
not used in the drive
parameter type
parameter number
Bl0001f1.fh7
*) parameter type uses bit 15 in "parameter number" and three further bits in the "parameter type" byte
Fig. 10-57:
Parameter type and number in the useful data header
Reaction Telegram
The reaction telegram is the telegram the slave (drive) sends to the
master (slave
→
master).
Ta0002f1.fh7
useful data
tel. header
status
byte
control
byte
device
address
useful data
header
1byte
1byte
1byte
Fig. 10-58:
Structure of the useful data header in the reaction telegram
In the status byte an error code is returned, if necessary. In the case of an
error-free transmission, a 0x00 is returned in the status byte.
The control byte contains the information regarding which data block
element of a parameter is accessed. Bit 2 controls the transmission of
sequential telegrams (writing lists in several steps).
In this byte the device address set at in the
P-0-4022, Drive address of
serial interface
parameter has to be entered.
In the useful data bytes it is possible to enter any value that is interpreted
in a different way according to the service. For flash programming, for
example, binary characters are entered in the useful data and when
writing a parameter the decimal numeric value is entered.
The number of bytes in the useful data field and of the useful data header
are entered in the DatL and DatLW bytes.
Status Byte Description
Kind of error
00h
error-free transmission
without error
01h
During the execution of the requested
service an error occurred. The
service-
specific error code
is contained in the
useful data of the reaction telegram.
execution error
F0h
The requested service is not supported by
the addressed slave.
telegram error
F8h
In the sequential telegram, data in the
telegram error
Status Byte
Control Byte
Device Address
Structure of the Useful Data
Field
Status Messages
Courtesy
of
CMA/Flodyne/Hydradyne
▪
Motion
Control
▪
Hydraulic
▪
Pneumatic
▪
Electrical
▪
Mechanical
▪
(800)
426-5480
▪