Note:
In open-loop-controlled U/f operation deceleration takes place
taking the delay entered in parameter
P-0-0569, Maximum
stator frequency change
into account!
•
S-0-0349, Jerk limit bipolar
•
S-0-0372, Drive Halt acceleration bipolar
The parameters take effect as described under "Drive Halt" in chapter
"Drive Functions".
The sequence of the error reaction with motor holding brake available is
described in chapter "Motor, Mechanical Axis System, Measuring
Systems" in section "General Information on the Operation of Motors with
IndraDrive" under "Motor Holding Brake: Error Situation 1".
Note:
The activation and function of the motor holding brake
depends on the setting in parameter
P-0-0525, Holding brake
control word
.
See Parameter Description "P-0-0525, Holding brake control
word"
See also "General Information on the Operation of Motors with IndraDrive:
Motor Holding Brake" in chapter "Motor, Mechanical Axis System,
Measuring Systems"
Switch to Torque-Free State
In the case of error the drive is switched to torque-free state. The drive in
this case is only braked by the friction torque; it "coasts to stop". The time
until standstill can be considerable, especially with spindles.
Note:
The "torque disable" error reaction is inevitable with fatal
errors (F8xxx), because braking, e.g. with a defective output
stage, is no longer possible!
DANGER
Drive continues to move unbraked in the case of
error!
Danger to life from parts in motion when the safety door
at the machining cell is opened!
⇒
Check drive for motion (e.g. using
S-0-0040, Velocity
feedback value
, if possible) and wait for standstill!
The sequence of the error reaction with motor holding brake available is
described in chapter "Motor, Mechanical Axis System, Measuring
Systems" in section "General Information on the Operation of Motors with
IndraDrive" under "Motor Holding Brake: Error Situation 2".
Note:
The activation and function of the motor holding brake
depends on the setting in parameter
P-0-0525, Holding brake
control word
.
See Parameter Description "P-0-0525, Holding brake control
word"
Pertinent Parameters
Sequence of Error Reaction with
Motor Holding Brake Available
P-0-0119 = 1 or Fatal Error
Sequence of Error Reaction with
Motor Holding Brake Available
Courtesy