Scope for Compulsory Certification of Products acc. first Catalogue" and put
in circulation in China. This compulsory certification has existed since 2003.
CNCA is the Chinese authority responsible for certification guidelines. When
a product is imported in China, the certification will be checked at customs
using the entries in a database. Three criteria are typically critical for certifica‐
tion being required:
1.
Customs tariff number (HS code) according to CNCA document "Appli‐
cation Scope for Compulsory Certification of Products acc. first Cata‐
logue".
2.
Area of application according to CNCA document "Application Scope for
Compulsory Certification of Products acc. first Catalogue".
3.
For the IEC product standard used, a corresponding Chinese GB stand‐
ard must exist.
For the drive components by Rexroth described in this documentation, certifi‐
cation is currently not required, so they are not CCC certified. Negative certifi‐
cations will not be issued.
4.2
Transport and storage
4.2.1
Transporting the components
Ambient and operating conditions for transport
Description
Symbol
Unit
Value
Temperature range
T
a_tran
°C
-20 … +70
Relative humidity
%
5 … 95
Absolute humidity
g/m
3
1 … 60
Climatic category (IEC 721)
2K3
Moisture condensation
Not allowed
Icing
Not allowed
Tab. 4-4:
Ambient and operating conditions for transport
4.2.2
Storing the components
Risk of damage to
KCU drive connection box
from long-term storage!
NOTICE
The KCU drive connection box contains electrolytic capacitors which may de‐
teriorate during storage. When storing the KCU drive connection box for a
longer period of time, run it once a year for at least 1 hour at 24 V control
voltage U
N3
.
Risk of damage to
KMV supply unit from
long-term storage!
NOTICE
The KMV supply unit contains electrolytic capacitors which may deteriorate
during storage. When storing the KMV supply unit for a longer period of time,
run it once a year for at least 1 hour at mains voltage U
LN
.